Nominal Flow |
Min Flow |
Max Pressure |
Max Temp |
|
Model |
Type |
Tube |
Liquid (Kg/hr) |
Gas (slpm) |
Liquid (Kg/hr) |
Accuracy |
bar |
psig |
C |
F |
Input/Output |

QMBC |
Precision Mass
Flow Controller
Gas and Liquid |
2
3
4 |
0.15
0.78
9.32 |
1.05
2.96
29.1 |
0.001
0.01
0.1 |
0.2%,
0.5%,
or 1.0% Rate |
100 |
1500 |
65 |
150 |
0-5 Vdc,
4-20 mA
or Hart |
 
|

QMBM |
Precision Mass
Flow Meter
Gas and Liquid |
2
3
4 |
0.19
1.00
13.5 |
1.43
5.60
50.4 |
0.001
0.01
0.1 |
±0.2%,
0.5%,
or 1.0% Rate |
100 |
1500 |
65 |
150 |
0-5 Vdc,
4-20 mA
or Hart |
  |
Model |
Capacity |
Output |
Compliance |

GCS400 Series |
60, 100, 300lbs |
4-20 mA
0.05-5.05 VDC |
CE |
 |
ANV/ANH Point Level Switch
The vertical (Series ANV) or horizontal (Series ANG) level switches are designed to detect level variations and activate alarms accordingly. They can be used for normal, corrosive, or hazardous liquids and are certified explosion-proof or intrinsically safe. Certified material, NACE, radiography options are available to meet customer specifications.

MR783 Multi-Point Level Switch
This multi-point level switch features a compact size, making it easy to mount in multiple locations on a tank. With versatile construction (316SS, PVC, or PVDF), the MR783 is certified explosion-proof or intrinsically safe and is capable of indicating more than one level per tank and triggers alarms accordingly.

|
|
Capacity Water |
|
|
Pressure |
|
Temp |
|
|
|
|
Model |
Type |
lph |
gpm |
Accuracy Rate |
bar |
psig |
C |
F |
Output |
Construction |
Connection |

BM01/02 |
Oval Gear Meter |
2 to 5000 |
0.008 to 2.2 |
1% |
10 |
150 |
-29 to 66 |
-20 to 150 |
Pulse |
316 SS or PPS |
Threaded |
 
|

BMO4/50 |
Oval Gear Meter |
60 to 21000 |
0.3 to 92.5 |
0.5% |
55 |
800 |
-29 to 120 |
-20 to 248 |
Pulse |
Aluminum, 316 SS or PPS |
Threaded and Flanged |
  |
Industrial Pressure Transducer and Transmitters
0254 Gas and Liquid Mass Flow Secondary Electronics, 4 channels
The Brooks 0254 is a four-channel power supply, readout, and set point controller. This innovative, reliable microcomputer-based controller provides power for up to four Brooks thermal mass flow, Quantim Coriolis mass flow, and/or pressure devices; all in a new compact design. Additionally, the 0254 can be used to generate flow setpoint commands, display flow rate, totalize flow, for blending multiple flow streams, and more. This fully RoHS compliant device has a very user-friendly operation and is offered with multiple mounting capabilities such as rack mount, panel mount, and table-top mount.

SLR Transducer Displays
The Brooks SLR series transducer display is a minature digital transducer display for use on 1.125 inch surface substrate. It is designed to interface to transducers with 30 PSI and 100 PSI full scale pressure ranges. The SLR series utilizes a Light Emitting Diode (LED) with two selectable engineering units (PSI and KPa) can can be rotated to be positioned at all four quadrants.
The SLR series has increased noise immunity and proprietary designs to provide extremely accurate pressure readings, even in the most challenging environments. The SLR series is electricaly interfaced using a high-density 15-pin D-Sub connector. The device uses an externally supplied 13 to 32 VDC excitation which in turn is supplied to the mating Brooks pressure transducer.


TD100 Pressure Transducer Displays
Local display of process pressure improves safety and quality control of the gas delivery systems. The Brooks TD100 series pressure transducer displays allow a 4-20mA sensor to digitally display its pressure and send its signal to a final destination. A sensor, such as the SolidSense II pressure transducers and transmitters, connects to either the back or bottom of the TD100 with a 4-pin Bendix connector. The TD100 connects to the loop through either a 6-wire pigtail cable or a 4-pin mail Bendix connector. The TD100 offers a real time reading. It is loop powered, single channeled, and can swivel around the transducer so the viewing angle can be adjusted. The display has red LED lighting for easy reading in low ambient light. The TD100 has two adjustable alarm setpoints.


LR056 Pressure Transducer Displays
Local display of process pressure improves safety and quality control of the gas delivery systems. The LR056 series pressure transducer display allows a 4-20mA sensor to digitally display its pressure and send its signal to a final destination. A sensor, such as the SolidSense II pressure transducers and transmitters, connects to either the back or bottom of the LR056 with a 4-pin Bendix connector. The LR056 connects to the loop through either a 6-wire pigtail cable or a 4-pin mail Bendix connector. The LR056 offers a real time reading. It is loop powered, single channeled. The LR056 has two user programmable setpoints which define a window - if the window is entered or left an output signal is generated.


Pressure Gauges
Pressure Transmitters
Model |
Type |
Full Scale Capacity |
Accuracy |
C |
F |
Output |
Power
Supply |

SFP33WA |
Flow Through -
Ultra Pure Water |
0-15 psig
up to
0-150 psig |
±1% FS |
15-40 |
59-104 |
4-20 mA |
24 Vdc |
SFP33CA |
Flow Through -
Chemicals, Acids, Bases |
0-15 psig
up to
0-150 psig |
±1% FS |
15-40 |
59-104 |
0-5V, 1-5V, 0-10V |
12-24 Vdc |
SFP32WA |
Single Ended -
Ultra Pure Water |
0-15 psig
up to
0-150 psig |
±1% FS |
15-40 |
59-104 |
0-5V, 1-5V, 0-10V |
12-24 Vdc |
SFP32CA |
Single Ended -
Chemicals, Acids, Bases |
0-15 psig
up to
0-150 psig |
±1% FS |
15-40 |
59-104 |
0-5V, 1-5V, 0-10V |
12-24 Vdc |
 |
Ultra-High Purity Pressure Transducers and Transmitters
General Purpose Thermal Mass Flow Controllers and Mass Flow Meters
Liquid Thermal Mass Flow Controllers & Mass Flow Meters
|
|
|
|
Max Pressure |
Max Temp |
|
Model |
Type |
Full Scale Capacity |
Accuracy |
bar |
psig |
C |
F |
Input/Output |

5881/91 |
Liquid Mass Flow
Controller &
Mass Flow Meter |
30 - 100 gr/hr. |
0.5% FS |
400 |
5800 |
65 |
150 |
0-5 Vdc, 4-20 mA |
 
|

5882/92 |
Liquid Mass Flow
Controller &
Mass Flow Meter |
200 - 1000 gr/hr. |
0.5% FS |
400 |
5800 |
65 |
150 |
0-5 Vdc, 4-20 mA |
  |
MultiFlo Capable Thermal Mass Flow Controllers & Mass Flow Meters
|
|
|
|
Max Pressure |
Max Temp |
|
Model |
Type |
Full Scale Capacity |
Accuracy |
bar |
psig |
C |
F |
Input/Output |

SLAMf Series |
Digital Mass Flow
Meter & Mass Flow Controller |
3 sccm - 2500 slpm |
0.7% Rate
and
0.2% FS |
100 |
1500 |
65 |
150 |
0-5 Vdc,
4-20 mA,
FOUNDATION fieldbus™,
RS-485 |
 
|

Mf-S Series |
Smart Mass Flow Meter &
Mass Flow Controller |
3 sccm - 36000 slpm |
0.7% Rate
and
0.2% FS |
100 |
1500 |
65 |
150 |
0-5 Vdc,
4-20 mA,
RS-232/485
PROFIBUS DP® |
 
|

Mfi Series |
Analog Mass Flow Meter &
Mass Flow Controller |
3 sccm - 1000 slpm |
1% FS |
100 |
1500 |
65 |
150 |
0-5 Vdc,
4-20 mA |
  |
|
|
|
|
Max Pressure |
Max Temp |
|
Model |
Type |
Full Scale Capacity |
Accuracy |
bar |
psig |
C |
F |
Input/Output |

SLAMf Series |
Digital Mass Flow
Meter & Mass Flow Controller |
3 sccm - 2500 slpm |
0.7% Rate
and
0.2% FS |
100 |
1500 |
65 |
150 |
0-5 Vdc,
4-20 mA,
FOUNDATION fieldbus™,
RS-485 |
 
|

Mf-S Series |
Smart Mass Flow Meter &
Mass Flow Controller |
3 sccm - 36000 slpm |
0.7% Rate
and
0.2% FS |
100 |
1500 |
65 |
150 |
0-5 Vdc,
4-20 mA,
RS-232/485
PROFIBUS DP® |
 
|

Mfi Series |
Analog Mass Flow Meter &
Mass Flow Controller |
3 sccm - 1000 slpm |
1% FS |
100 |
1500 |
65 |
150 |
0-5 Vdc,
4-20 mA |
  |
Obsolete Mass Flow Meters (elastomer sealed)
Model |
Brand(s) |
Brooks Instrument Replacement(s) |
FM360
FM361 |
Celerity
Mykrolis
Millipore
Tylan General
Tylan |
4860, GF40, 5850E or 5850TR |
FM362 |
Celerity
Mykrolis
Millipore
Tylan General
Tylan |
SLA5861 or 5861E (≤100 slpm) |
FM380
FM380SA |
Celerity
Mykrolis
Millipore
Tylan General
Tylan |
5860E, GF40 or SLA5860 |
FM3900
FM3910 |
Celerity
Mykrolis
Millipore
Tylan General
Tylan |
5860E, GF40 or SLA5860 (≤30 slpm) |
FM3920
FM3921 |
Celerity
Mykrolis
Millipore
Tylan General
Tylan |
5861E or SLA5861 (≤100 slpm)
5863E or SLA5863 (≥100 slpm) |
180C |
Celerity
Unit |
4850, GF40 or 5850E |
7300 |
Celerity
Unit |
SLA5860 or GF40 |
7301 |
Celerity
Unit |
SLA5860 or GF40 |
8100 |
Celerity
Unit |
SLA5860 or GF40 |
8101 |
Celerity
Unit |
SLA5860 or GF40 |
Model |
Range FS
(Torr) |
Measurement Range |
Operating Temp
(oC) |
Accuracy |
Temp. Coefficient |
Output Signial |
CMC Series |
10, 20, 50,
100, 200, 500 |
3.5 Decades
(from FS) |
unheated |
0.25% to 0.50% of Reading |
0.005% of FS/oC (Zero)
0.027% of FX/oC (Span) |
0-10 VDC |
  |
XacTorr CMX45 |
0.1, 1, 2, 10
20, 100, 1000 |
4 Decades
(from FS) |
45 |
0.25% or 0.50% of Reading /
0.15% of Reading /
0.25% of Reading |
0.002% of FS/oC (Zero)
0.02% of FX/oC (Span) |
Analog (9pin or 15pin D-Sub), RS485, DeviceNet |
  |
XacTorr CMX100 |
0.1, 1, 2, 10
20, 100, 1000 |
4 Decades
(from FS) |
100 |
0.25% of Reading /
0.15% of Reading /
0.25% of Reading |
0.002% of FS/oC (Zero)
0.02% of FX/oC (Span) |
Analog (9pin or 15pin D-Sub), RS485, DeviceNet |
  |
XacTorr CMX160 |
0.1, 1, 2, 10
20, 100, 1000 |
4 Decades
(from FS) |
160 |
N/A /
0.25% or 0.35% of Reading /
0.50% of Reading |
0.002% of FS/oC (Zero)
0.02% of FX/oC (Span) |
Analog (9pin or 15pin D-Sub), RS485, DeviceNet |
  |
|
Capacity
-Water |
Capacity
-Air |
|
|
Max
Pressure |
Temp |
|
Model |
lph |
gph |
m3n/hr |
scfm |
Accuracy Rate |
bar |
psig |
C |
F |
Output |

MT3809 |
25
to
100000 |
.11
to
440 |
0.78
to
1404 |
0.49
to
888 |
2% |
103 |
1500 |
-29
to
325 |
-20
to
617 |
Alarm and/or
4-20 mA, HART
(IS or X-Proof) |
 
|
MT3819 |
110
to
15000 |
0.48
to
66 |
3.2
to
435 |
2
to
275 |
2% |
19 |
275 |
-29
to
150 |
-20
to
300 |
Alarm and/or
4-20 mA, HART
(IS or X-Proof) |
 
|
MT3810 |
25
to
20000 |
0.11
to
88 |
0.78
to
620 |
0.49
to
392 |
5% |
103 |
1500 |
-29
to
215 |
-20
to
420 |
Alarm and/or
4-20 mA, HART
(IS or X-Proof) |
 
|

3600 Series |
18
to
11355 |
0.08
to
50 |
0.65
to
43 |
0.38
to
28 |
10% |
103 |
1500 |
-29
to
204 |
-20
to
400 |
Alarm
(IS or X-Proof) |
 
|
3750 |
0.8
to
100 |
003
to
44 |
.04
to
3.1 |
.02
to
2 |
5% |
275 |
4000 |
-29
to
204 |
-20
to
400 |
Alarm and/or
4-20 mA
(IS or X-Proof) |
  |
Control Valve, Fine Control
Brooks Model 8500 Series NRS (non-rising stem) control valves are designed specifically for extremely low-flow gas and liquid applications. Straight and 90o angle pattern models in brass or stainless steel are available. They feature a means of adjusting a sliding tapered needle which prevents sticking. These valves are particularly suitable for precise control and possess a high turns-to-lift ratio. The flow is constant for any given stem position.



CCB311 Flow Switch
Brooks flow switches are rugged, robust and reliable for usage in harsh and hazardous environments. Flow switches are designed to detect various flow rates in industrial process lines and activate an alarm or pump.
The CCB311 flow switch is designed to detect low flows in horizontal or vertical pipes with an upward flow direction. Suitable for liquids for gases, the CCB311 flow switch is very robust with high repeatability and a very basic design. Certified explosion-proof or intrinsically safe.

|
Capacity
-Water |
Capacity
-Air |
|
Max
Pressure |
Temp |
|
Model |
lph |
gph |
m3n/hr |
scfm |
Accuracy Rate |
bar |
psig |
C |
F |
Output |
GT1000 |
0.024
to
22392 |
0.0001
to 98 |
0.002
to 431 |
0.001
to 273 |
2% FS |
34 |
500 |
1
to
121 |
33
to
250 |
Alarm (IS) |
 
|
1100 Series |
0.032
to
29300 |
0.0001
to 129 |
0.002
to 342 |
0.001
to 217 |
2% FS |
34 |
500 |
1
to
121 |
33
to
250 |
Local
Indication
Only |
 
|
1306 |
31
to
2205 |
0.14
to 9.7 |
1.2
to 66 |
0.8
to 42 |
3% FS |
24 |
350 |
1
to
121 |
33
to
250 |
Local
Indication
Only |
 
|
1307 |
39
to
20900 |
0.17
to 92 |
1.5
to 342 |
0.9
to 217 |
2% FS |
24 |
350 |
1
to
121 |
33
to
250 |
Local
Indication
Only |
 
|
1305 |
182
to
11355 |
0.8
to 50 |
4.7
to 79 |
3
to 50 |
10% FS |
14 |
200 |
1
to
121 |
33
to
250 |
Alarm |
 |
1358 |
182
to
1136 |
48
to
300 |
5.4
to
23.6 |
3.4
to
15 |
10% FS |
14 |
200 |
1
to
121 |
33
to
250 |
Glass Tube w/
316 SS |
 
|
|
Capacity
-Water |
Capacity
-Air |
|
Max
Pressure |
Temp |
|
Model |
lph |
gph |
m3n/hr |
scfm |
Accuracy Rate |
bar |
psig |
C |
F |
Output |

1350 |
0.032
to
114 |
0.006
to
30 |
0.002
to
3.7 |
0.001
to
2.33 |
10% FS |
14 |
200 |
1
to
121 |
33
to
250 |
Glass Tube w/
Aluminum,
Brass or 316 SS |
 
|

1355 |
0.032
to
114 |
0.006
to
30 |
0.002
to
3.7 |
0.001
to
2.33 |
5% FS |
14 |
200 |
1
to
121 |
33
to
250 |
Glass Tube w/
Aluminum,
Brass or 316 SS |
 
|

1358 |
182
to
1136 |
48
to
300 |
5.4
to
23.6 |
3.4
to
15 |
10% FS |
14 |
200 |
1
to
121 |
33
to
250 |
Glass Tube
w/ Brass or
316 SS |
 
|

1250 |
0.032
to
114 |
0.006
to
30 |
0.002
to
3.7 |
0.001
to
2.3 |
10% FS |
14 |
200 |
1
to
93 |
33
to
200 |
Glass Tube w/
Aluminum,
316 SS |
 
|

1255 |
0.032
to
114 |
0.006
to
30 |
0.002
to
3.7 |
0.001
to
2.3 |
5% FS |
14 |
200 |
1
to
93 |
33
to
200 |
Glass Tube w/
Aluminum,
316 SS |
 
|
Manual Flow Controller
Brooks Model FC8800 Series flow controllers are designed to maintain a constant differential pressure across an integral manual flow regulating valve. Series 8800 controllers are designed for all liquid and gas flows with constant downstream pressures; series 8900 controllers are for all liquid and gas flows with constant upstream pressures.


Manual Precision Flow Controller, Tight Shutoff
Brooks Model FC8744 NRS (non-rising stem) flow controllers accurately adjust and maintain small gas flows. They are designed for constant upstream, variable downstream applications. Suitable for precise control, this valve possesses a high turns-to-lift ratio which provides stable flow for any given stem position.


|
Capacity
-Water |
Capacity
-Air |
|
|
Max
Pressure |
Temp |
|
Model |
lph |
gph |
m3n/hr |
scfm |
Accuracy Rate |
bar |
psig |
C |
F |
Output |

2510 |
.24
to
14.5 |
.2
to
40 |
.002
to
5.5 |
.002
to
3.3 |
5% FS |
6.8 |
100 |
65 |
100 |
Plastic tube
w/ Brass or 303SS |
 
|

2520 |
.24
to
220 |
1
to
66 |
.002
to
5.5 |
.002
to
3.3 |
3% FS |
6.8 |
100 |
65 |
100 |
Plastic tube
w/ Brass or 303SS |
 
|

2530 |
.8
to
20 |
12
to
300 |
.76
to
30 |
.5
to
20 |
3% FS |
6.8 |
100 |
65 |
100 |
Plastic tube
w/ Brass or 303SS |
 
|

2540-S /
2540-V
2540-I |
60
to
4500 |
24
to
11200 |
5.5
to
165 |
3
to
100 |
2% FS |
6.8 |
100 |
65 |
100 |
Plastic tube
w/ PVC or 303SS |
  |
Model 1198 Flow Indicator
Brooks Instrument Model 1198 flow indicators provide quick, reliable and economical way to verity fluid flows through industrial process lines. Model 1198 is available with three styles of indicators including paddle wheel, flap style or drip tube/whistle shape. Many specials are also available upon request to meet various conditions of pressure, temperature, fluid types and mechanical dimensions.